The LASERDOPP® PV 2000 Vascular Microlaboratory

Recent clinical studies have documented the high diagnostic assuracy of Skin Perfusion Pressure (SPP) measurements on patients with ischemic ulcerations.

SPP succeeds where tcPO2 fails . . . 

You may currently be performing tcPO2 tests to evaluate the microcirculatory status at wound sites.  If so, we don't need to tell you about warmup time, calibration, and other aspects that extend the test time to 40 - 45 minutes ¯ except the LASERDOPP PV 2000 doesn't require any warmup time, and there isn't any calibration to do either.  As a result, you can complete the SPP test in less than 10 minutes - a time savings of over ½ hour per patient!
The PV2000 works where other instruments don't...
No problem for the LASERDOPP System.

Calcification makes segmental pressures unreliable...
No problem for the LASERDOPP System.

Sensitive Skin may not tolerate heated tcPO2 electrodes...
No problem for the LASERDOPP System.

 

The PV2000 is fast and easy to operate...
The Laserdopp System combines laser  Doppler  
technology and SPP methods  developed by John J.  
Castronuovo, MD, for  noninvasive evaluation of
microcirculation.

 - Simple to use.  No warmup or calibration.

 - No searching for inaudible pulses.

 - No membrances to change.

 - Printed report at the touch of a button.

  ...and performs a PVR®...

Easy to interpret results
Pulse Volume Waveform available on thigh, calf,     
ankle, transmetatarsal and toes.
 
 
 
 
 
 
 
 
* PVR is a registered trademark of Life Sciences, Inc.
* LASERDOPP is a registered trademark of Vasamedics.

 
Specifications

Laser

Power at light exit:  1.8 mW typical

Wavelength:  780 nm

Classification:  Class I (per CFR 1040.10 and 1040.11)

Zeroing:  None required


Blood Voume Measurement
Range: 0-10% tissue hematocrit calculated, 0-5% maximum graphic display

Averaging Time:  3 seconds

Pressure Measurement
Mean Pressure Range:  0-200 mmHg

Pulse Volume Waveform:  1-30 Hz frequency response

Transducer Type:  Solid state

Ordering Information
Catalog Numbers
PV 2000 Vascular Microlaboratory (specify 100, 115, 220, or 240V operation).  Includes LTP-10, -20, -30, sphygmo, trolley, and printer
LTP-10 Digit transducer for SPP and PV Waveform measurements
LPT-20 Transmetatarsal (foot) transducer for SPP and PV Waveform measurements
LPT-30 Leg Transducer for SPP and PV Waveform measurements
44300 Printer with interface cable for connection to PV 2000 (one included with PV 2000)
43350 Compact Trolley with room for the PV 2000, printer, printer paper, and LPT's
44100 Sphygmomanometer