NeuroMuscular System/3
Manufactured by Neurodyne
Medical
ANNOUNCING THE ONLY
SURFACE EMG WITH ALL OF THESE FEATURES
The
NeuroMuscular System/3 |
- Two, Four or Eight
channels of computerized EMG measurement
- Preamplified
sensors for unequaled accuracy
- Dynamic wide-band
muscle monitoring
- EMG threshold
control of neuromuscular stimulators
- Standardized
protocols for biofeedback training
- Raw EMG sound
|
Programs
that are easy to use and easy to modify
The NeuroMuscular
System/3 has the flexibility that you need now, and in the
future. the System/3 is self documenting and so user
friendly that you can begin using it immediately...without help.
Standard programs incorporate clinically proven protocols, but
allow modification of most parameters. On-screen prompts
guide you through changes. You can save your own custom
protocols in a software library or as patient specific
procedures.
Superior
Instrumentation
The Neuromuscular
System/3 supports two, four or eight channels of surface EMG for
a full range of dynamic & functional assessment applications
and associated biofeedback training.
The System/3 features
the Active Electrode, a compact sensor assembly that includes a
miniaturized instrument preamplifier. Locating the
amplifier at the electrode site cancels artifacts before being
transferred down the electrode cable, resulting in a superior
signal. Wide frequency band monitoring well below 100 Hz
is provided to support accurate recording of fatigued muscles, a
feature not included in most traditional surface EMGs.
|
|
THE
SPECIFICS
Software
- Fully
integrated, high performance EMG system with
computer interface.
- Software
allows complete control over session
configuration, including user defined conditions
such as work/rest sets, and provides clinically
appropriate, positive visual and auditory
feedback for reinforcing the training goals.
- Software
is easy to modify. Save your changes as
custom protocols and build your own library of
general and patient specific procedures.
- Advanced
documentation of muscle activity and patient
progress is provided through graphic displays,
automated data reduction, and printed reports.
- Software
controlled triggers turn neuromuscular
stimulators on and off. Unique dual
stimulator triggers provide both synchronous and
reciprocal capability.
- Raw EMG
sound provides dynamic tool for monitoring
muscle activity and provides clear artifact
detection.
|
|
EMG and stimulation, a
powerful combination
EMG control of
stimulators bridges the gap between voluntary and involuntary
movement, resulting in enhanced patient motivation and
accelerated progress. Optically isolated stimulator
outputs allow the use of most commercially available NMS devices
with externally triggered inputs. The stimulator is
activated by exceeding the selected EMG threshold.
Automated record
keeping and report generation
Session data is saved for
each patient in a
database on the hard disk drive. Programs collect this
data automatically and produce session reports that include
baseline, threshold, mean and min/max values for each trial.
The detailed data option allows you to also save the raw data
from a session for later playback. You can enter your
comments for any session, making note taking simple and
convenient. And, you can review or print any portion of a
patients record at any time. Reports are suitable for
insurance claims or referral sources.
|
HARDWARE /
INSTRUMENTATION
| EMG |
Available
with 2, 4 or 8 channels of surface EMG Calibrated EMG
range: 0.01 - 1000 µV
Input Bias
Current: Less than 2.0 Picoamperes
Differential
Input Impedance: Greater than 1,000,000 Megohms
Common Mode
Rejection: 125 dB (100 Hz) 150 db (60 Hz)
Bandwidth:
25-450 Hz. (60 Hz. Notch filter)
Noise:
Less than 0.05 µV (inputs shorted).
Signal
Quantification: microvolts RMS.
(Raw EMG
outputs available as custom option) |
| Audio |
Raw EMG
Sound: Front panel selectable, by channel |
| Triggers |
Two software
activated triggered outputs for neuromuscular
stimulators. Normally closed electronic
switches. 7500 VDC optical isolation.
2.5mm phone connectors |
| Audio |
Inputs:
Stereo line level inputs. 1V RMS. nom. 3.5mm
phone connector.
Outputs:
Stereo output for 8 ohm speakers, headphones.
Power output 2 watts/channel at 0.05% distortion.
3.5mm phone connector. |
| Outputs |
Analog
outputs suitable for connection to chart recorders,
oscilloscopes, etc.
Full optical
isolation for up to 8 channels, 7500V. (AC 5s,
<10pA leakage at 120 VAC). DB15 connector. |
| Physical |
Power sealed
gel-cell rechargeable battery, 3 A/hr. 30 hours
typical between charges.
Front panel low
BAT/CHG indicator. (6A/hr. dual battery for 8
channel).
Console:
14.4"W X 10.2"D X 4.3"H
Weight:
Console: 9lbs. (12lbs for 8 channel
configuration) |
| I/O |
- PCI card,
or
- USB
cable, or
- PCMCIA
card
|
|
| All rights
reserved. Specifications subject to change without notice. System/3,
Active Electrode are trademarks of NeuroDyne Medical Corp. |

Toll
Free: 1-888-667-2324
Tel: 613-256-2821
|
|