Home



Contact Us


What's New


Muscle Testing
Physiotherapy



Muscle Testing
Products


Muscle Stimulation Products

Equipment Recommendation Form


  

 

 

 

 

 


< Back to products page
< Back to Muscle Testing EMG

MEGA WIN 
 

MegaWin is a versatile, easy to use software package for recording, analysis and training. No matter what type of muscle testing and analysis you need, — in clinical applications, research, sports or occupational — you can produce outstanding results quickly and reliably with MegaWin.  It's the only complete solution for all of your surface EMG measurement and analysis functions in one fully integrated software package.

 

Minimum Hardware Requirements

Optional Hardware Requirements
Major Features Data Analysis Products
What's New

MegaWin is a full-featured biosignal management software system for recording and analyzing multi-channel surface EMG, along with related positional data and video imagery.  It gives fast windows-based analysis.  The same software can be effectively used for both fast routine testing and in-depth functional analysis. 




Applications include:
  •    Ergonomic analysis
  •    Functional testing
  •    Biomechanical research
  •    Physical therapy
  •    Muscle dysfunction            analysis
  •    Sports medicine
While including the most comprehensive set of software tools available for detailed in-depth analysis, MegaWin is also designed for quick start-up using the supplied default values. It is intended to be configured for your specific analysis requirements and for your specific hardware.

It is not necessary to learn different software systems for assessments, occupational analysis, functional testing and muscle training.  With MegaWin you can do it all.  There is superb ease of use and the highest possible functionality. 

 


Minimum Hardware Requirements

  • ME-6000 Biomonitor, ME-3000P series muscle tester with 2, 4 or 8 channels, MESPEC-4000, ME-3000 Muscle Trainer,  or Inco Trainer.
  • Pentium II computer, with Windows 98, Windows ME or Windows NT version 4.0 service pack 3 or later, Windows 2000, Windows XP.
  • 233 MHz, 64 MB RAM, 100 MB available disk space, available PCI slot, or USB port, CD-ROM drive, 17" XGA monitor, or notebook with active matrix display and 1024 x 768 resolution at 85 Hz refresh rate and 16 bit colour. 
 
Optional Hardware Supported
  • ME3000P-ISO Isolation Unit — 2 channels of force, position, inclination.
  • Goniometer Amplifier — 2 channels of angle or torque using P+G sensors.
  • ME-3000-P Video Option — Video recording and playback synchronized with EMG.  Records on computer hard drive using MJPEG (Motion JPEG) format. 
  • Foot Switch — 2 channels for gait analysis.
  • Video Camera — Composite video (RCA cable) or S-video.
Major Features
  • EMG recording modes  —  averaged (linear envelope) and raw
  • EMG display modes  —  averaged (linear envelope), muscle trainer and raw
  • Selectable 1, 2, 4, 6 or 8 or 16 channels
  • Recording methods
  • Offline measurements with data  download
  • Real-time measurement, display and recording 
  • Muscle trainer monitor
  • Audio voice prompts
  • Reference level calibration by six selectable methods, for both off-line and real-time measurements
  • Measured Maximal Voluntary Contraction (MVC) or Acceptable Maximal Effort (AME)
  • Measured average
  • Measured dynamic average with specified trigger level
  • Manual set
  • Previous reference
  • Specified default level
  • EMG units of measure — µV or % MVC
  • EMG scaling — Auto scaling or set value
  • Metric units of measure
  • Adjustable parameters for calculations
  • Test subject / patient data base
  • Measurement data base
  • Import - Export to other MegaWin measurement data bases
  • ASCII, Matlab, EDF, C3D Motion Analiysis and Peak Motus export
  • Signal configuration editor, total of eight channels — for defining the signal channel assignments — EMG, angle, torque, force, position, inclination
  • Protocol controlled measurements
  • Multiple user and password support with access restrictions
  • Conversion of data to ASCII
  • Conversion of Mega data files created by MS-DOS based muscle tester software
  • Data backup
  • Multiple hardware configuration editor
  • Protocol editor
  • On-line graphical muscle atlas and locator
  • Video monitor  (1 to 4 cameras) displays live video during measurements - (Requires ME-3000-P Video Option.        
    Video is not available for Windows NT.)
  • On-line video capture and replay
  • Single frame snap-shot
  • Off-line video and EMG recording — EMG synchronization by marker button and flash unit
  • Video compression ratio adjustments
  • Synchronization with external motion analysis systems.

Data Analysis
  • Graphical and numerical display of Basic results
    • Cumulative amplitude distributions
    • Work / loading - bilateral differences
    • Onset slope with activation times
    • Activation order
    • Onset times
    • Peak values
    • Physiologic gaps - level, density, duration
    • Marker events
    • Cursor analysis
    • Stimulus analysis (optional)
  • Zoom in, zoom out
  • Selectable areas of interest
  • Spectrum Analysis, Fast Fourier Transform (FFT) showing median frequency, mean power frequency and zero crossing rate
    • Single spectrum
    • Average spectrum
    • Fatigue test
  • Normative database of fatigue tests
  • Follow-up analysis with trend reports