Programs that
are easy to use and easy to modify
The NeuroMuscular System/3
has the flexibility that you need now, and in the future. the System/3
is self documenting and so user friendly that you can begin using it immediately...without
help. Standard programs incorporate clinically proven protocols,
but allow modification of most parameters. On-screen prompts guide
you through changes. You can save your own custom protocols in a
software library or as patient specific procedures.
Superior Instrumentation
The Neuromuscular System/3
supports two, four or eight channels of surface EMG for a full range of
dynamic & functional assessment applications and associated biofeedback
training.
The System/3 features the
Active Electrode, a compact sensor assembly that includes a miniaturized
instrument preamplifier. Locating the amplifier at the electrode
site cancels artifacts before being transferred down the electrode cable,
resulting in a superior signal. Wide frequency band monitoring well
below 100 Hz is provided to support accurate recording of fatigued muscles,
a feature not included in most traditional surface EMGs. |
THE SPECIFICS
Software
Fully integrated, high performance
EMG system with computer interface.
Software allows complete control
over session configuration, including user defined conditions such as work/rest
sets, and provides clinically appropriate, positive visual and auditory
feedback for reinforcing the training goals.
Software is easy to modify.
Save your changes as custom protocols and build your own library of general
and patient specific procedures.
Advanced documentation of muscle
activity and patient progress is provided through graphic displays, automated
data reduction, and printed reports.
Software controlled triggers
turn neuromuscular stimulators on and off. Unique dual stimulator
triggers provide both synchronous and reciprocal capability.
Raw EMG sound provides dynamic
tool for monitoring muscle activity and provides clear artifact detection.
|
|
EMG and stimulation,
a powerful combination
EMG control of stimulators
bridges the gap between voluntary and involuntary movement, resulting in
enhanced patient motivation and accelerated progress. Optically isolated
stimulator outputs allow the use of most commercially available NMS devices
with externally triggered inputs. The stimulator is activated by
exceeding the selected EMG threshold.
Automated record keeping
and report generation
Session data is saved for
each patient, either on individual patient disks or in a database on the
hard disk drive. Programs collect this data automatically and produce
session reports that include baseline, threshold, mean and min/max values
for each trial. The detailed data option allows you to also save
the raw data from a session for later playback. You can enter your
comments for any session, making note taking simple and convenient.
And, you can review or print any portion of a patients record at any time.
Reports are suitable for insurance claims or referral sources. |
HARDWARE / INSTRUMENTATION
| EMG |
Available with
2, 4 or 8 channels of surface EMG Calibrated EMG range: 0.01 - 1000 µV
Input Bias Current:
Less than 2.0 Picoamperes
Differential Input Impedance:
Greater than 1,000,000 Megohms
Common Mode Rejection: 125
dB (100 Hz) 150 db (60 Hz)
Bandwidth: 25-450 Hz. (60
Hz. Notch filter)
Noise: Less than 0.05
µV (inputs shorted).
Signal Quantification:
microvolts RMS.
(Raw EMG outputs available
as custom option) |
| Audio |
Raw EMG Sound: Front
panel selectable, by channel |
| Triggers |
Two software activated triggered
outputs for neuromuscular stimulators. Normally closed electronic
switches. 7500 VDC optical isolation. 2.5mm phone connectors |
| Audio |
Inputs: Stereo line
level inputs. 1V RMS. nom. 3.5mm phone connector.
Outputs: Stereo output
for 8 ohm speakers, headphones. Power output 2 watts/channel at 0.05%
distortion. 3.5mm phone connector. |
| Outputs |
Analog outputs suitable
for connection to chart recorders, oscilloscopes, etc.
Full optical isolation for
up to 8 channels, 7500V. (AC 5s, <10pA leakage at 120 VAC).
DB15 connector. |
| Physical |
Power sealed gel-cell rechargeable
battery, 3 A/hr. 30 hours typical between charges.
Front panel low BAT/CHG
indicator. (6A/hr. dual battery for 8 channel).
Console: 14.4"W X
10.2"D X 4.3"H
Weight: Console:
9lbs. (12lbs for 8 channel configuration) |
| I/O Card |
Resides in computer, 1/2
size or full size IBM / ISA standard slot. Provides up to 8 simultaneous
channels of A/D conversion with constant 14 bit resolution, 50 µs/channel.
(PCMCIA card option for laptops) |
|